Steel Rhino Property Inspections
Steel Rhino Property Inspections
Steel Rhino Property Inspections
Steel Rhino Property Inspections
Steel Rhino Property Inspections
Standard Inspections
Standard Inspections

A complete inspection with a written report designed to inform and
educate a buyer about the overall condition of the home.

Move-in Certified Inspections
Move-in Certified Inspections

For Sellers who want to know what is wrong, and gives them the opportunity to repair the home before a Buyers inspector finds problems.

Builder’s Warranty Inspections
Builder’s Warranty Inspections

This is a great tool for homeowners who purchase a "New Home".
This inspection is normally conducted before the builders warranty expires.

Maintenance Inspections
Maintenance Inspections

There are more than 3,000 operating components in a home and they do wear out. This occurs quietly and slowly, simple to overlook.

Commercial Inspections
Commercial Inspections

These inspections are designed for understanding the facility as well as looking out for the safety of anyone that may be entering the premises.

previous arrowprevious arrow
next arrownext arrow

Carbon monoxide (CO), is a colorless, odorless and tasteless gas which moves with air. It is highly toxic to humans and animals in higher quantities, although it is also produced in normal animal metabolism in low quantities, and is thought to have some normal biological functions.

It consists of one carbon atom and one oxygen atom, connected by a triple bond which consists of two covalent bonds as well as one dative covalent bond. It is the simplest oxocarbon, and is an anhydride of formic acid.

Carbon monoxide is produced from the partial oxidation of carbon-containing compounds; it forms when there is not enough oxygen to produce carbon dioxide (CO2), such as when operating a stove, furnace, or an internal combustion engine in an enclosed space. In presence of oxygen, carbon monoxide burns with a blue flame, producing carbon dioxide.

Because CO is impossible to see, taste or smell the toxic fumes, CO can kill you before you are aware it is in your home. At lower levels of exposure, CO causes mild effects that are often mistaken for the flu. These symptoms include headaches, dizziness, disorientation, nausea and fatigue. The effects of CO exposure can vary greatly from person to person depending on age, overall health and the concentration and length of exposure.

Average levels in homes without gas stoves vary from 0.5 to 5 parts per million (ppm). Levels near properly adjusted gas stoves are often 5 to 15 ppm and those near poorly adjusted stoves may be 30 ppm or higher. We recommend using an exhaust vent anytime you have a gas stove on to remove CO and other unburned gasses from the home.

It is most important to be sure combustion equipment is maintained and properly adjusted. Vehicular use should be carefully managed adjacent to buildings and in vocational programs. Additional ventilation can be used as a temporary measure when high levels of CO are expected for short periods of time.

  • Keep gas appliances properly adjusted.
  • Consider purchasing a vented space heater when replacing an unvented one.
  • Use proper fuel in kerosene space heaters.
  • Install and use an exhaust fan vented to outdoors over gas stoves.
  • Open flues when fireplaces are in use.
  • Choose properly sized wood stoves that are certified to meet EPA emission standards. Make certain that doors on all wood stoves fit tightly.
  • Have a trained professional inspect, clean, and tune-up central heating system (furnaces, flues, and chimneys) annually. Repair any leaks promptly.
  • Do not idle the car inside garage.

Standards or Guidelines

The OSHA standard for workers is no more than 50 ppm for 1 hour of exposure. The National Institute for Occupational Safety and Health (NIOSH) recommends no more than 35 ppm for 1 hour. The U.S. National Ambient Air Quality Standards for CO (established in 1985) are 9 ppm for 8 hours and 35 ppm for 1 hour. The Consumer Product Safety Commission recommends levels not to exceed 15 ppm for 1 hour or 25 ppm for 8 hours.

The EPA set two national health protection standards for CO: a one-hour standard of 35 parts per million and an eight-hour standard of 9 parts per million. Across the nation, air quality stations measure the levels of CO and other pollutants in the air. These measurements are compared to the standards. Areas that have CO levels that are too high must develop and carry out plans to reduce CO emissions.

Reducing emissions of CO is an important part of EPA's strategy for cleaner air. The U.S. Environmental Protection Agency (EPA), states, and local governments work as partners to reduce emissions of CO. EPA's main approaches to reduce CO have been to establish national ambient air quality standards, to require national controls for motor vehicle emissions, and to require reductions from large industrial facilities.

At what level does carbon monoxide become toxic?
For healthy adults, CO becomes toxic when it reaches a level higher than 50 ppm (parts per million) with continuous exposure over an eight hour period.. When the level of CO becomes higher than that, a person will suffer from symptoms of exposure. Mild exposure over a few hours (a CO level between 70 ppm and 100 ppm) include flu-like symptoms such as headaches, sore eyes and a runny nose. Medium exposure (a CO level between 150 ppm to 300 ppm) will produce dizziness, drowsiness and vomiting. Extreme exposure (a CO level of 400 ppm and higher) will result in unconsciousness, brain damage and death.

How to avoid carbon monoxide poisoning

  • Have a qualified technician install and regularly inspect all fuel burning appliances
  • Regularly inspect fireplaces and chimneys to insure proper ventilation
  • Never use a gas or charcoal barbeque indoors
  • Never start a car or gas run lawnmower or snow blower in a closed garage
  • Install a carbon monoxide detector in your home.

The U.S. Consumer Product Safety Commission recommends that a carbon monoxide detector be installed outside bedrooms. If the home has separate sleeping areas, a detector should be placed in each area. It is also recommended that one carbon monoxide detector should be installed on each level of the house. And for split-bedroom arrangements, the detector should be placed in a common area where everyone can hear the alarm.

Many of the detectors are able to be plugged into an electrical outlet; others are wall or ceiling mounted. As CO moves with air, it is affected by furnace supply and return vents, windows, exhaust vents in the home, and natural air flow or draw. In determining the best location and type of CO detector you should examine the area for obstructions and best possible air flow. CO detectors do not operate well if air is not moving by the device.

Ceiling units should be placed with care, as hot air rises in the home, the hot air packs densely at the ceiling, making it difficult for CO to pass through the air and pass to the devises sensor. Steel Rhino recommends that flat ceilings not have a CO detector on the ceiling but instead mounted not closer to the ceiling than 7” below the ceiling level.

Household chemicals should be stored at least 5 feet away from the detectors to prevent damage to the alarm. Additionally, locate the detector away from fuel-burning appliances, gas and wood-burning stoves or engines to prevent the alarm from being accidentally triggered.

The Occupational Safety and Health Administration and the Environmental Protection Agency suggest that an exposure to between 9 and 50 ppm for up to eight hours every twelve months can be considered safe for healthy adults. Similarly, according to the Consumer Product Safety Commission, most healthy adults will not experience any symptoms from prolonged exposure to CO levels of approximately 1 to 70 ppm, but as CO levels rise to above 70 ppm, flu-like symptoms will become apparent. Concentration levels above 150 ppm can cause disorientation, unconsciousness and death, as well as long-term neurological effects.

According to Underwriters Laboratory Standard 2034, home CO detector alarms must sound whenever they measure any of these carbon monoxide levels:

• 70 ppm for four hours
• 150 ppm for 50 minutes
• 400 ppm for 15 minutes

It's important to note that this standard is based on the likelihood of CO poisoning symptoms in an average healthy adult.
Other important numbers:

• Alarm tones must reach a decibel level of 85
• CO detectors should be replaced every five years

Misconceptions about CO Detectors

If you had an early model carbon monoxide detector and it didn't operate reliably, understand that the technology has been dramatically updated and several design flaws have been corrected. A few important cautions:

  • Do a little research before you make a purchase. Not all CO detectors are the same; some are demonstrably better than others.
  • Don't base your selection solely on the item's cost.
  • Don't be quick to decide that your CO detector is malfunctioning if the alarm goes off occasionally. Instead, have your furnace checked before you return the device to the store where you purchased it.
  • If your alarm sounds and an HVAC dealer or other professional tells you it's not your furnace or water heater, get a second opinion. Not all service technicians have the proper testing equipment.

Steel Rhino Property Inspections is proud to have installed your Kidde CO detectors in a location that is best suited to air movement which will sound when CO levels above the prescribed levels are detected in the home.

If you have any questions concerning the placement and location for your CO detectors, don’t hesitate calling.